THE WATER BLOCK

THE WATER BLOCK

The pools

The JHR is a pool-type nuclear reactor,
i.e. most of the reactor operations
using the reactor or the experimental
devices are performed under water:

The water block

CLICK ON A COMPONENT:

  • The water block
  • EPT
  • EPI
  • RER
  • REE
  • Transfer channel
  • EPU
  • EPO
  • EPM
  • EPC
  • Double-door transfer channel

Reactor cooling system

This material test reactor is cooled by water circulating in three independent systems:

The primary system cools the reactor core with water circulating under pressure. This closed system is located inside the reactor building
The secondary system is designed to cool the primary system through a series of heat exchangers positioned between these two separate systems in the reactor building.
The external/ tertiary system then cools the secondary cooling system through another set of heat exchangers located in a different building (the cooling water building).

The first two systems are closed. Only the tertiary system is open as it gets its water from the SCP-EDF Canal (Boutre-Carros in Vinon-sur-Verdon) upstream, before releasing it further downstream near the Cadarache centre entrance). The maximum upstream-downstream temperature difference of this water is 1.5°C in compliance with regulations.

The volume of water drawn from the EDF canal and transiting through the JHRis estimated to reach about 40 million m3/year, with a peak flow up to 3 m3/s and an average flow of 1.3 m3/s.

The primary system water temperature should be around 25°C at the core inlet to comply with the reactor’s operating conditions and will be below 60°C at the core outlet.